BUFX4(data type: typ)

Function
Y=A

 

Static Power:

When Static Power [nW]
- 0.0543

 

Port:

Name Direction
A INPUT
Y OUTPUT

 

Name Pin Capacitance [pF]
Rise Fall
A 0.0204 0.0204

 

Output Driving Strength

Name Rise Fall
Strength (sec/F) Limit (pF) Strength (sec/F) Limit (pF)
Y 478 1.66 431 1.66

 

Link To Path

PATH WHEN
(01A=>01Y) -
(10A=>10Y) -
 

 

(01A=>01Y)

DELAY [ns]

cl[pF] 0.06 0.16 0.32 0.8 1.6
ts[ns]
0.06 0.15 0.203 0.282 0.513 0.895
0.18 0.179 0.232 0.31 0.54 0.922
0.42 0.215 0.271 0.349 0.578 0.96
0.6 0.236 0.292 0.37 0.599 0.98
1.2 0.279 0.337 0.417 0.645 1.03

 

POWER [pJ]

cl[pF] 0.06 0.16 0.32 0.8 1.6
ts[ns]
0.06 0.42 0.422 0.425 0.43 0.431
0.18 0.461 0.448 0.447 0.451 0.451
0.42 0.592 0.567 0.544 0.535 0.533
0.6 0.701 0.661 0.639 0.619 0.612
1.2 1.09 1.01 0.966 0.918 0.896

Back To Path Index

 

(10A=>10Y)

DELAY [ns]

cl[pF] 0.06 0.16 0.32 0.8 1.6
ts[ns]
0.06 0.162 0.217 0.29 0.498 0.843
0.18 0.2 0.254 0.327 0.534 0.878
0.42 0.262 0.315 0.388 0.596 0.94
0.6 0.296 0.353 0.427 0.635 0.978
1.2 0.398 0.458 0.535 0.743 1.09

 

POWER [pJ]

cl[pF] 0.06 0.16 0.32 0.8 1.6
ts[ns]
0.06 0.586 0.589 0.586 0.592 0.595
0.18 0.63 0.627 0.624 0.624 0.625
0.42 0.747 0.727 0.719 0.713 0.714
0.6 0.857 0.824 0.804 0.793 0.791
1.2 1.25 1.17 1.13 1.09 1.08

Back To Path Index


(c)Simplex Solution Inc. 2001